Flexible molecules seldom exist as a single structure, and what is more, their most stable conformer can very well be in the minority. At room temperature they are found as a mixture of conformers, each one populated according to its free energy, so if three or four of them lie within a couple of kcal/mol above the global minimum, together they will outnumber it. Whatever we measure in the lab (NMR shifts, an optical rotation, a UV-Vis band) comes from all of them at once, and this is why calculating a property only for the lowest energy structure is one of those things that is mostly done wrong. What we need is a Boltzmann weighted average over all the relevant conformers. Here’s a short guide on how to get it done.

We start by optimizing every suspected relevant conformer and running a frequency calculation on each of them, all at the same level of theory, making sure they are all true minima (no imaginary frequencies). From each output file we take the value labeled Sum of electronic and thermal Free Energies, which is the electronic energy plus the thermal correction to the Gibbs free energy, and we convert it from Hartrees to kcal/mol by multiplying it by the corresponding factor of 627.5095. Then we take the difference between the free energy of each conformer and that of the most stable one (eq. 1), so the lowest conformer sits at zero and all the others have a positive value.

ΔGᵢ = Gᵢ − Gₘᵢₙ (eq. 1)

Next we calculate the Boltzmann factor of each conformer (eq. 2), where T is the temperature (298.15 K unless you changed it) and R is the gas constant, 1.987 × 10⁻³ kcal/(mol K).

wᵢ = exp(−ΔGᵢ / RT) (eq. 2)

Please bear two things in mind here. The first one is the negative sign in the exponent, without which the least stable conformer turns out to be the most populated one. The second one is the constant, because our energies are given per mole and thus we must use the gas constant R, which is nothing but Boltzmann’s constant times Avogadro’s number, in the same units as ΔG; at 298.15 K the product RT is 0.5925 kcal/mol.

The sum of the Boltzmann factors of all the conformers is the partition function, Q, and the population of each conformer is its own Boltzmann factor divided by Q (eq. 3), which multiplied by 100 translates to the percentage of each conformer in the mixture.

pᵢ = wᵢ / Q, where Q = Σ wᵢ (eq. 3)

For the sake of the example, let’s say a conformational search yielded four conformers, A through D, with the following free energies (I made these numbers up, so don’t go looking for the molecule).

ConformerG (Hartrees)ΔG (kcal/mol)exp(−ΔG/RT)Population (%)
A-652.1847310.001.000048.79
B-652.1843220.260.648431.64
C-652.1837680.600.360617.60
D-652.1817021.900.04041.97
Sum2.0495100.00

Conformer A is the global minimum and yet it accounts for less than half of the molecules, while B and C, both within 0.6 kcal/mol, account together for about the other half, and D, at 1.9 kcal/mol, barely reaches 2%. As a rule of thumb, at room temperature every 1.36 kcal/mol (RT ln 10) lowers the Boltzmann factor tenfold, so conformers lying more than 3 kcal/mol above the minimum contribute less than 1% each and can usually be left out. The populations must add up to 100%, which is worth checking but it is not proof of anything, since a wrong sign or a wrong constant will still add up to a perfect 100%. A better test is that the populations decrease as ΔG increases, and if all your conformers turn out to be equally populated then take a look at the exponent of R.

With the populations at hand, the Boltzmann average of any property X is just the sum of the values calculated for each conformer weighted by their populations (eq. 4), written as fractions and not as percentages.

⟨X⟩ = Σ pᵢ Xᵢ (eq. 4)

Suppose the specific rotations calculated for our four conformers were +42.0, −35.5, −88.3 and +15.2 (made up again). The Boltzmann average is −6.0, whereas the global minimum alone would have given us +42.0, which is not a slight change but the opposite sign altogether. Bear also in mind that the plain arithmetic mean (−16.7) is not the answer either, because it gives conformer D and its meager 2% the same weight as conformer A.

A few words of caution are in order. Populations depend exponentially on ΔG, so an error of only 0.5 kcal/mol, which is well within the accuracy of most DFT methods, changes a Boltzmann factor by more than a factor of two; use the best level of theory you can afford and do not read too much into the second decimal. Flexible molecules also have low frequency modes which are poorly described by the harmonic approximation and contaminate the entropy term, so a quasi-harmonic correction (GoodVibes will do it for you) goes a long way. If a conformer has an equivalent twin you did not calculate, like the two gauche forms of butane, multiply its Boltzmann factor by its degeneracy. Finally, Gaussian calculates the thermal corrections at 298.15 K by default, so if your experiment was run at a different temperature use the Temperature keyword in the frequency calculation and that same value of T in eq. 2.

The whole thing fits in a spreadsheet, and it’s pretty easy to automatize with a Python script (stay tuned!). As usual, thanks for reading, commenting, and sharing.