Failure Reading NMR data in GaussView

There was this following message on a GIAO calculation when trying to open the file in GaussView5.0 (it opens successfully in ChemCraft)

CConnectionGLOG::Parse_GLOG()
Failure reading NMR data 
Line Number 2414

When you go to said line (line 2414) you find the following string:

Eigenvalues:-12345.6789 -12345.6789 -12345.6789

Which belong to the eigenvalues of the SCF NMR GIAO shielding tensor. The problem lies with the space missing between the colon sign ‘:’ and the ‘-‘ sign of the first eigenvalue. You can fix it either by hand with an editor but GV only warns you about the first instance so there may be others and you need to repeat the procedure. It is probably best to fix them all in one go with the following command from the terminal:

sed -i ‘s/Eigenvalues:-/Eigenvalues: -/g’

It is good to be back in Romania at the UBB writing these posts where this blog began. Thanks to my good friend Dr. Alexandru Lupan for pointing out this error.

About joaquinbarroso

Theoretical chemist in his early forties, in love with life and deeply in love with his woman and children. I love science, baseball, literature, movies (perhaps even in that order). I'm passionate about food and lately wines have become a major hobby. In a nutshell I'm filled with regrets but also with hope, and that is called "living".

Posted on May 20, 2019, in Computational Chemistry and tagged , , , , , , , , , , . Bookmark the permalink. Leave a comment.

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Google photo

You are commenting using your Google account. Log Out /  Change )

Twitter picture

You are commenting using your Twitter account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

Connecting to %s

%d bloggers like this: